FT1210
  • 12-volts
  • GC12 Group Size
  • 321 mins @ 25 amps
  • 70 mins @ 75 amps
  • 110 AH @ 5HR
  • 140 AH @ 20HR
  • 1505 CA @ 32°C
  • 1210 CCA @ 0°C
FT1210

FT1210 High Capacity Dual Purpose AGM Battery

Cycling Capacity
20 hour rate 140 Amp Hours
Reserve Capacity
@ 25 Amps 321 minutes @ 75 Amps 70 minutes
Mechanical Specifications
Group Size GC12
Terminal Type M8
Total Height 10.75" (273 mm)
Height 10.59" (269 mm)
Width 7.17" (182 mm)
Length 12.87" (327 mm)
Weight 94.8 lbs (43 kg)
Case Type ABS Plastic - Flame Res Rating UL94-HB
Discharge Table (Constant Current)
Time Amps Rate
20 hr 7 0.05 CA
10 hr 13 0.1 CA
8 hr 14.8 0.13 CA
5 hr 23 0.25 CA
3 hr 32.2 0.33 CA
2 hr 44.1 0.5 CA
1 hr 80 1 CA
Electrical Specifications
Nominal Voltage 12 Volt
Capacity @ 100 hour rate 144 AH
Capacity @ 20 hour rate 140 AH
Capacity @ 10 hour rate 130 AH
Capacity @ 5 hour rate 110 AH
CCA 1210
CA or MCA 1505
Short Circuit Current 5000 Amps
Internal Resistance 3.5m Ω
Charge Voltages
Battery Voltages
Charge Stage 12V 24V 36V 48V
Bulk 14.7 V 29.4 V 44.1 V 58.8 V
Absorption 14.7 V 29.4 V 44.1 V 58.8 V
Float 13.6 V 27.2 V 40.8 V 54.6 V
TC Factor: -4mV/°C/cell
Temperature Range Specifications
Condition Recommended Maximum
Storage -15°C to 50°C -40°C to 71°C
Operation -15°C to 40°C -40°C to 71°C
Charge with TC -15°C to 50°C -40°C to 71°C
Charge without TC 0°C to 40°C -15°C to 50°C
Terminal Torque Specifications
Terminal Type ft-lbs in-lbs Nm
AP | DT (AP) | M6 | M6M (stud) | TP07 (AP) | TP08 (AP) 4.2 - 6.15 50-85 5.6 - 7.24
FR45 6.0 - 7.20 70-105 7.9 - 10.16
M8 | LT 7.1 - 8.15 85-110 9.6 - 10.22
DT (stud) | M10M (stud) 9.2 - 10.19 110-140 12.2 - 14.15
  Name Size
Charging Instructions Icon Charging Instructions 1.1 MB
Installation Manual Icon Installation Manual 1.7 MB
Spec-sheet Icon Spec-sheet 1.6 MB
Product Menu