FFD110-12
  • 12-volts
  • 31 Group Size
  • 205 mins @ 25 amps
  • 50 mins @ 75 amps
  • 82 AH @ 5HR
  • 110 AH @ 20HR
  • 1050 CA @ 32°C
  • 850 CCA @ 0°C
FFD110-12

FFD110-12 Dual Purpose AGM Battery

Cycling Capacity
20 hour rate 110 Amp Hours
Reserve Capacity
@ 25 Amps 205 minutes @ 75 Amps 50 minutes
Mechanical Specifications
Group Size 31
Terminal Type M8 (w/ TP08 Brass AP Included)
Total Height 9.49" (241 mm)
Height 8.43" (214 mm)
Width 6.77" (172 mm)
Length 12.91" (328 mm)
Weight 66.1 lbs (30 kg)
Case Type ABS Plastic - Flame Res Rating UL94-HB
Discharge Table (Constant Current)
Time Amps Rate
20 hr 5 0.05 CA
10 hr 9 0.1 CA
8 hr 10.6 0.13 CA
5 hr 16.4 0.25 CA
3 hr 28 0.33 CA
2 hr 32.5 0.5 CA
1 hr 60.6 1 CA
Electrical Specifications
Nominal Voltage 12 Volt
Capacity @ 100 hour rate 115 AH
Capacity @ 20 hour rate 110 AH
Capacity @ 10 hour rate 90 AH
Capacity @ 5 hour rate 82 AH
CCA 850
CA or MCA 1050
Short Circuit Current 2650 Amps
Internal Resistance 9m Ω
Charge Voltages
Battery Voltages
Charge Stage 12V 24V 36V 48V
Bulk 14.7 V 29.4 V 44.1 V 58.8 V
Absorption 14.7 V 29.4 V 44.1 V 58.8 V
Float 13.6 V 27.2 V 40.8 V 54.6 V
TC Factor: -4mV/°C/cell
Temperature Range Specifications
Condition Recommended Maximum
Storage -15°C to 50°C -40°C to 71°C
Operation -15°C to 40°C -40°C to 71°C
Charge with TC -15°C to 50°C -40°C to 71°C
Charge without TC 0°C to 40°C -15°C to 50°C
Terminal Torque Specifications
Terminal Type ft-lbs in-lbs Nm
AP | DT (AP) | DT (stud) | M6 | M6M (stud) | TP07 (AP) | TP08 (AP) 4.2 - 6.0 50-70 5.6 - 7.9
FR45 6.0 - 7.5 70-90 7.9 - 10.1
M8 | LT 7.1 - 8.0 85-95 9.6 - 10.7
M10M (stud) 9.2 - 10.4 110-125 12.2 - 14.0
  Name Size
Charging Instructions Icon Charging Instructions 1.1 MB
Installation Manual Icon Installation Manual 1.7 MB
Spec-sheet Icon Spec-sheet 328.8 KB